SingleCellSingleCell Request a quote
Рус EN

SingleCell LLC · sequencing laboratory · Saint Petersburg

Single-cell RNA sequencing (scRNA-seq)

scRNA-seq turns a sample into a map of individual cells: it shows which cells are present, what state they are in and which genes are active in each of them.

Applications: oncology and the tumor microenvironment · hematology · immunology and vaccines · microbiology, virology and infectious disease · neurobiology · embryology and developmental biology · cell therapy and regenerative medicine · zoology and model organisms · botany and agricultural biotechnology · mycology

from ₽160,000scRNA-seq 3′ · per sample
from ₽190,0005′ with TCR/BCR · per sample
from 20 daysbusiness days · depends on the project

00 Services

Request a quote →

    Minimum prices are shown; the final price is confirmed in the quote; discounts from 10 samples. The per-sample price covers incoming QC, library preparation and sequencing. Bioinformatics: from ₽5,000 per sample, including cell types, differential expression, pathways, vector figures, Materials and Methods, an interactive map and a results review via video call.

    01 Technology

    01 / 06

    Samples we accept

    We accept tissue, including tumor tissue, blood, cell suspensions, nuclei, FFPE blocks, RNA, DNA and existing data – from organizations only, under contract and de-identified.

    sample requirements

    02 / 06

    From tissue to sequencing-ready library

    Enzymatic dissociation of tissue into a cell suspension, removal of non-viable cells.

    Cells are partitioned into droplets with barcoded beads: mRNA molecules are tagged with a cell barcode and a UMI.

    depth 25,000 read pairs per cellquality Q30 ≥ 85%

    Libraries are prepared on the MobiDrop platform with MobiCube kits and sequenced paired-end on the SURFSeq 5000.

    Deliverable: FASTQ files with checksums and a run quality report.

    Additional bioinformaticsOrdered separately, from ₽5,000 per sample, including for your existing data.matrix generation and cell QCcell type annotationgroup comparisonpathway analysiscell–cell interactionsand much more

    03 / 06primary processing

    Gene × cell matrix

    We build the expression matrix from the reads and run cell quality control.

    Deliverable: expression matrix after quality control and a quality control report MTX · H5 · H5AD · RDS

    You can stop at this stage or continue to cell population analysis.

    04 / 06cell populations

    Cell population map

    Automated cell type annotation validated with marker genes.

    Dot size: fraction of cells expressing the gene; color: mean expression

    Deliverable: cell map + populations, proportions and markers.

    Available as a separate stage.

    05 / 06comparison

    What differs between groups

    We compare groups within each cell population: composition, genes and pathways.

    differentially expressed genes in the selected population

    key pathways distinguishing the groups
    Cell type proportions: normal vs tumor

    Deliverable: differences between groups, gene lists and key pathways.

    Available as a separate stage.

    06 / 06reporting

    Report: all results in one document

    automated cell type annotationcell types and their proportionsgroup comparisons: normal / tumor, before / after, control / treatmentgenes and pathways distinguishing the groupspublication-ready figuresmaterials and methods

    Deliverable: an interactive report with figures.

    02 What you get

    Without bioinformaticsFASTQ · checksums · run quality report
    With bioinformaticsFASTQ · checksums · run quality report · expression matrix · data analysis · interactive report · publication-ready figures
    Standard parameters
    • scRNA-seq – ≥ 25,000 read pairs/cell
    • bulk RNA-seq – ≥ 30 M read pairs/sample
    • Q30 ≥ 85%
    • mapping rate ≥ 80%*
    • turnaround: scRNA-seq from 20 · bulk RNA-seq from 15 business days

    * human and mouse, with standard sample quality

    What we guarantee and what depends on the sample

    Guaranteed and specified in the contract: read quality (Q30 ≥ 85%), sequencing depth at least as ordered, mapping rate ≥ 80% (human, mouse), WGS/WES coverage. The scRNA-seq turnaround is counted from incoming sample QC. Work is paused to investigate if the fraction of reads in cells drops below 60% (nuclei – 50%). We report but do not guarantee, as they depend on the sample: the actual number of cells, median genes and UMIs per cell, mitochondrial RNA fraction, doublet rate and the fraction of cells with a productive receptor. Repeats caused by the laboratory are at our expense; if there is a problem with a sample, we propose options before the next stage is paid for.

    03 Sample workflow

    Five steps – from request to report.

    04 Request

    we will contact you
    Select a service
    Number of samples: 1 to 80. For more samples, write to info@singlecell.ru and we will prepare a custom quote.
    Please enter a valid email address
    Do not include personal data of patients or donors.
    Please confirm that you have read the Privacy Policy
    Check the box to consent to the processing of your personal data

    What happens next

    1. We contact youby email or phone to discuss your project and samples
    2. We send a quotetogether with sample instructions
    • minimum order – one sample
    • no registration required
    • we work with organizations under contract

    Or write to us directly: info@singlecell.ru

    05 FAQ